EnglishEnglish
Professional Heat Pump Manufacturer Since 2005
You are here: Home / Products / Domestic Heat Pump / Multi-function Heat Pump / Fixed Frequence Air to Water Heat Pump Water Heater

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
sharethis sharing button

Fixed Frequence Air to Water Heat Pump Water Heater

 
1. Max. COP: 4.19

2. Power Supply: 220V/50Hz/1P

3. Running Temp: -7℃~40℃

4. Heating Capacity Range: 2KW-8KW

5. Multi-functions: Hot Water/House Heating/House Cooling
Availability:
Quantity:

fasfsd图片2


Simplicity Description

  Our household compact split type (Fluorine cycle) air source heat pumps are designed for domestic hot water and floor heating. They have the following important features:

  Split design allows you to install the outdoor unit outside,which is much quieter.The installation can be more flexible.

  Spiral coil heating exchanger,which is more efficient for heat exchanging,energy-saving and more durable inside Water Tank is adapted by 316 stainless steel.

  With 24-month long warranty for main configuration such as compressor electrical controller,etc,Meidibao Fixed Frequence Split Type Air to Water Heat Pumps are designed for domestic hot water,room heating and cooling with operating ambient temperature from -7℃ to 40℃.

  They are featured with anti-freezing Protection-Split model design to better avoid freezing problem and automatic anti-freezing protection by detecting system water temperature.


图片2


Key Components of MEIDIBAO Split Type Compact Series Air Source Heat Pump


split type pic3

图片2


Introduction of WILO Water Pump and Working Principle

Hc6b27219e6e2413486c1b18800f1cd0cu图片2


Application Diagram


H7035a6eadad7457fb567fe0821451562B

图片2


Specification

Rated working condition: dry-bulb temp: 7℃; wet-bulb temp: 2℃; cool water temp: 30℃; hot water temp: 35℃.

Climate
T2 Climate
T2
Model
M-D03SAH Model
M-D05SAH
power supply P/V/HZ 1/220/50 Power supply P/V/HZ 1/220/50
Rated Heating Capacity(A7℃/W35℃) KW 3.56 Rated heating Capacity(A7℃/W35℃) KW 5.25
Rated input Capacity KW 0.85 Rated input Capacity KW 1.28
COP W/W 4.19 COP W/W 4.11
Rated current A 3.9 Rated current A 5.8
Hot water volume L/H 76 Hot water volume L/H 113
Maximum input power KW 1.1 Maximum input current KW 1.6
Maximum input current A 5 Maximum input current A 7.2
Refrigerant/Volume G R410A/950

Refrigerant/Volume

G R410A/1200

Maximum discharge pressure

MPa 4.2 Maximum discharge   pressure MPa 4.2
Minimum suction pressure MPa 0.15 Minimum suction   pressure MPa 0.15
Rated water   temperature 55 Rated water   temperature 55
Maximum water   temperature 60 Maximum water   temperature 60
Noise dB(A) 43 Noise dB(A) 44
Anti-electric shock Rate / I Anti-electric shock Rate / I
Protection level / IP× 4 Protection level / IP× 4
Net dimension MM 780×260×550 Net dimension MM 780×260×550
Net weight KG 27 Net weight KG 29
Production date / code showed on   machine body Production date / code showed on   machine body
Factory number code: / code showed on   machine body Factory number code: / code showed on   machine body




Climate
T2 Climate
T2
Model
M-D08SAH Model
M-D06SAH
power supply P/V/HZ 1/220/50 Power supply P/V/HZ 1/220/50
Rated Heating   Capacity(A7℃/W35℃) KW 8.75 Rated heating   capacity(A7℃/W35℃) KW 6.3
Rated input   Capacity KW 2.13 Rated input Capacity P/V/HZ 1.61
COP W/W 4.11 COP W/W 3.92
Rated current A 9.7 Rated current A 7.3
Hot water   volume L/H 188 Hot water volume L/H 135
Maximum input power KW 2.8 Maximum input current KW 2.1
Maximum input current A 12.7 Maximum input current A 9.5
Refrigerant/Volume G R410A/1600 Refrigerant/Volume G R410A/1550
Maximum discharge pressure MPa 4.2 Maximum discharge   pressure MPa 4.2
Minimum suction pressure MPa 0.15 Minimum suction   pressure: MPa 0.15
Rated water   temperature 55 Rated water   temperature 55
Maximum water   temperature 60 Maximum water   temperature 60
Noise dB(A) 47 Noise dB(A) 45
Anti-electric shock Rate / I Anti-electric shock Rate / I
Protection level / IP× 4 Protection level / IP× 4
Net dimension MM 780×260×550 Net dimension MM 795×290×540
Net weight KG 36 Net weight KG 43
Production date / code showed on   machine body Production date / code showed on   machine body
Factory number code / code showed on   machine body Factory number code / code showed on   machine body



Climate
T2
Model
M-D02SAH
power supply P/V/HZ 1/220/50
Rated Heating Capacity(A7℃/W35℃) KW 2.2
Rated input Capacity KW 0.68
COP W/W 3.24
Rated current A 3.1
Hot water volume L/H 31
Maximum input power KW 0.88
Maximum input current A 4
Refrigerant/Volume G R134A/700
Maximum discharge pressure MPa 3.0
Minimum suction pressure MPa 0.05
Rated water temperature 55
Max water temperature 60
Noise dB(A) 43
Anti-electric shock Rate / I
Protection level / IP× 4
Net dimension MM 780×260×550
Net weight KG 27
Production date / code showed on machine body
Factory number code / code showed on machine body

  

Previous: 
Next: 

Product Category

QUICK LINKS

Home
 中文网站:meidibao.com.cn
Commercial Heat Pump Water Hearter

FOLLOW US

  +86-0757-25668403
 +86-13534489875
  No9,Guangming North Road, Jiangyi, Leliu, Shunde, Foshan, Guangdong,China
CONTACT US
Copyright © 2021 Foshan Meidibao Electrical Appliance Co.,Ltd. All rights reserved.