Availability: | |
---|---|
Quantity: | |
Simplicity Description
Our household compact split type (Fluorine cycle) air source heat pumps are designed for domestic hot water and floor heating. They have the following important features:
Split design allows you to install the outdoor unit outside,which is much quieter.The installation can be more flexible.
Spiral coil heating exchanger,which is more efficient for heat exchanging,energy-saving and more durable inside Water Tank is adapted by 316 stainless steel.
With 24-month long warranty for main configuration such as compressor electrical controller,etc,Meidibao Fixed Frequence Split Type Air to Water Heat Pumps are designed for domestic hot water,room heating and cooling with operating ambient temperature from -7℃ to 40℃.
They are featured with anti-freezing Protection-Split model design to better avoid freezing problem and automatic anti-freezing protection by detecting system water temperature.
Key Components of MEIDIBAO Split Type Compact Series Air Source Heat Pump
Introduction of WILO Water Pump and Working Principle
Application Diagram
Specification
Rated working condition: dry-bulb temp: 7℃; wet-bulb temp: 2℃; cool water temp: 30℃; hot water temp: 35℃.
Climate | T2 | Climate | T2 | ||
Model | M-D03SAH | Model | M-D05SAH | ||
power supply | P/V/HZ | 1/220/50 | Power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 3.56 | Rated heating Capacity(A7℃/W35℃) | KW | 5.25 |
Rated input Capacity | KW | 0.85 | Rated input Capacity | KW | 1.28 |
COP | W/W | 4.19 | COP | W/W | 4.11 |
Rated current | A | 3.9 | Rated current | A | 5.8 |
Hot water volume | L/H | 76 | Hot water volume | L/H | 113 |
Maximum input power | KW | 1.1 | Maximum input current | KW | 1.6 |
Maximum input current | A | 5 | Maximum input current | A | 7.2 |
Refrigerant/Volume | G | R410A/950 | Refrigerant/Volume | G | R410A/1200 |
Maximum discharge pressure | MPa | 4.2 | Maximum discharge pressure | MPa | 4.2 |
Minimum suction pressure | MPa | 0.15 | Minimum suction pressure | MPa | 0.15 |
Rated water temperature | ℃ | 55 | Rated water temperature | ℃ | 55 |
Maximum water temperature | ℃ | 60 | Maximum water temperature | ℃ | 60 |
Noise | dB(A) | 43 | Noise | dB(A) | 44 |
Anti-electric shock Rate | / | I | Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 | Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 | Net dimension | MM | 780×260×550 |
Net weight | KG | 27 | Net weight | KG | 29 |
Production date | / | code showed on machine body | Production date | / | code showed on machine body |
Factory number code: | / | code showed on machine body | Factory number code: | / | code showed on machine body |
Climate | T2 | Climate | T2 | ||
Model | M-D08SAH | Model | M-D06SAH | ||
power supply | P/V/HZ | 1/220/50 | Power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 8.75 | Rated heating capacity(A7℃/W35℃) | KW | 6.3 |
Rated input Capacity | KW | 2.13 | Rated input Capacity | P/V/HZ | 1.61 |
COP | W/W | 4.11 | COP | W/W | 3.92 |
Rated current | A | 9.7 | Rated current | A | 7.3 |
Hot water volume | L/H | 188 | Hot water volume | L/H | 135 |
Maximum input power | KW | 2.8 | Maximum input current | KW | 2.1 |
Maximum input current | A | 12.7 | Maximum input current | A | 9.5 |
Refrigerant/Volume | G | R410A/1600 | Refrigerant/Volume | G | R410A/1550 |
Maximum discharge pressure | MPa | 4.2 | Maximum discharge pressure | MPa | 4.2 |
Minimum suction pressure | MPa | 0.15 | Minimum suction pressure: | MPa | 0.15 |
Rated water temperature | ℃ | 55 | Rated water temperature | ℃ | 55 |
Maximum water temperature | ℃ | 60 | Maximum water temperature | ℃ | 60 |
Noise | dB(A) | 47 | Noise | dB(A) | 45 |
Anti-electric shock Rate | / | I | Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 | Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 | Net dimension | MM | 795×290×540 |
Net weight | KG | 36 | Net weight | KG | 43 |
Production date | / | code showed on machine body | Production date | / | code showed on machine body |
Factory number code | / | code showed on machine body | Factory number code | / | code showed on machine body |
Climate | T2 | |
Model | M-D02SAH | |
power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 2.2 |
Rated input Capacity | KW | 0.68 |
COP | W/W | 3.24 |
Rated current | A | 3.1 |
Hot water volume | L/H | 31 |
Maximum input power | KW | 0.88 |
Maximum input current | A | 4 |
Refrigerant/Volume | G | R134A/700 |
Maximum discharge pressure | MPa | 3.0 |
Minimum suction pressure | MPa | 0.05 |
Rated water temperature | ℃ | 55 |
Max water temperature | ℃ | 60 |
Noise | dB(A) | 43 |
Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 |
Net weight | KG | 27 |
Production date | / | code showed on machine body |
Factory number code | / | code showed on machine body |
Simplicity Description
Our household compact split type (Fluorine cycle) air source heat pumps are designed for domestic hot water and floor heating. They have the following important features:
Split design allows you to install the outdoor unit outside,which is much quieter.The installation can be more flexible.
Spiral coil heating exchanger,which is more efficient for heat exchanging,energy-saving and more durable inside Water Tank is adapted by 316 stainless steel.
With 24-month long warranty for main configuration such as compressor electrical controller,etc,Meidibao Fixed Frequence Split Type Air to Water Heat Pumps are designed for domestic hot water,room heating and cooling with operating ambient temperature from -7℃ to 40℃.
They are featured with anti-freezing Protection-Split model design to better avoid freezing problem and automatic anti-freezing protection by detecting system water temperature.
Key Components of MEIDIBAO Split Type Compact Series Air Source Heat Pump
Introduction of WILO Water Pump and Working Principle
Application Diagram
Specification
Rated working condition: dry-bulb temp: 7℃; wet-bulb temp: 2℃; cool water temp: 30℃; hot water temp: 35℃.
Climate | T2 | Climate | T2 | ||
Model | M-D03SAH | Model | M-D05SAH | ||
power supply | P/V/HZ | 1/220/50 | Power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 3.56 | Rated heating Capacity(A7℃/W35℃) | KW | 5.25 |
Rated input Capacity | KW | 0.85 | Rated input Capacity | KW | 1.28 |
COP | W/W | 4.19 | COP | W/W | 4.11 |
Rated current | A | 3.9 | Rated current | A | 5.8 |
Hot water volume | L/H | 76 | Hot water volume | L/H | 113 |
Maximum input power | KW | 1.1 | Maximum input current | KW | 1.6 |
Maximum input current | A | 5 | Maximum input current | A | 7.2 |
Refrigerant/Volume | G | R410A/950 | Refrigerant/Volume | G | R410A/1200 |
Maximum discharge pressure | MPa | 4.2 | Maximum discharge pressure | MPa | 4.2 |
Minimum suction pressure | MPa | 0.15 | Minimum suction pressure | MPa | 0.15 |
Rated water temperature | ℃ | 55 | Rated water temperature | ℃ | 55 |
Maximum water temperature | ℃ | 60 | Maximum water temperature | ℃ | 60 |
Noise | dB(A) | 43 | Noise | dB(A) | 44 |
Anti-electric shock Rate | / | I | Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 | Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 | Net dimension | MM | 780×260×550 |
Net weight | KG | 27 | Net weight | KG | 29 |
Production date | / | code showed on machine body | Production date | / | code showed on machine body |
Factory number code: | / | code showed on machine body | Factory number code: | / | code showed on machine body |
Climate | T2 | Climate | T2 | ||
Model | M-D08SAH | Model | M-D06SAH | ||
power supply | P/V/HZ | 1/220/50 | Power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 8.75 | Rated heating capacity(A7℃/W35℃) | KW | 6.3 |
Rated input Capacity | KW | 2.13 | Rated input Capacity | P/V/HZ | 1.61 |
COP | W/W | 4.11 | COP | W/W | 3.92 |
Rated current | A | 9.7 | Rated current | A | 7.3 |
Hot water volume | L/H | 188 | Hot water volume | L/H | 135 |
Maximum input power | KW | 2.8 | Maximum input current | KW | 2.1 |
Maximum input current | A | 12.7 | Maximum input current | A | 9.5 |
Refrigerant/Volume | G | R410A/1600 | Refrigerant/Volume | G | R410A/1550 |
Maximum discharge pressure | MPa | 4.2 | Maximum discharge pressure | MPa | 4.2 |
Minimum suction pressure | MPa | 0.15 | Minimum suction pressure: | MPa | 0.15 |
Rated water temperature | ℃ | 55 | Rated water temperature | ℃ | 55 |
Maximum water temperature | ℃ | 60 | Maximum water temperature | ℃ | 60 |
Noise | dB(A) | 47 | Noise | dB(A) | 45 |
Anti-electric shock Rate | / | I | Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 | Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 | Net dimension | MM | 795×290×540 |
Net weight | KG | 36 | Net weight | KG | 43 |
Production date | / | code showed on machine body | Production date | / | code showed on machine body |
Factory number code | / | code showed on machine body | Factory number code | / | code showed on machine body |
Climate | T2 | |
Model | M-D02SAH | |
power supply | P/V/HZ | 1/220/50 |
Rated Heating Capacity(A7℃/W35℃) | KW | 2.2 |
Rated input Capacity | KW | 0.68 |
COP | W/W | 3.24 |
Rated current | A | 3.1 |
Hot water volume | L/H | 31 |
Maximum input power | KW | 0.88 |
Maximum input current | A | 4 |
Refrigerant/Volume | G | R134A/700 |
Maximum discharge pressure | MPa | 3.0 |
Minimum suction pressure | MPa | 0.05 |
Rated water temperature | ℃ | 55 |
Max water temperature | ℃ | 60 |
Noise | dB(A) | 43 |
Anti-electric shock Rate | / | I |
Protection level | / | IP× 4 |
Net dimension | MM | 780×260×550 |
Net weight | KG | 27 |
Production date | / | code showed on machine body |
Factory number code | / | code showed on machine body |